| Rated flow: |
50 gpm (72000 gpd) |
| Electrical requirement: |
230 VAC, 60 Hz, 1 phase, 20 amp total |
| Feed pump: |
3/4 HP self priming centrifugal cast iron with
thermally protected motor. |
| Discharge pump: |
1 1/2 HP cast iron with thermally protected
motor. Supplies pressurized water to car or truck wash, or other
use. |
| Electrical controls: |
Prewired with 20 amp plug, 10 ft cord
Power switch, lighted
NEMA 4 rated enclosure
|
| Oxidizer metering pump: |
Electronic controlled diaphragm pump with stroke
rate and stroke length controls and automatic degassing head.
Injects oxidizer reagent in water to disinfect and deodorize |
| Holding and collection tanks: |
Two 1000 gallon polyethylene conical bottom
tanks. With inlet, outlet, and solids discharge piping. |
| Centrifugal solids separator: |
Removes heavy solids (sand and grit) prior to
filter system and delivers them to a holding container for
disposal. |
| Filter system: |
High capacity permanent element filter system
with automatic backwash. |
| Make up water: |
Flow as required for application, 100 psi maximum
pressure |
| Connection sizes: |
Feed pump inlet- 1 1/2 NPT
Treated water outlet- 1 1/2 NPT
Make up water- 1/2 NPT
|
| Overall dimensions: |
Two tanks 6 ft diameter, 7 ft tall Control and
pumping module 4 ft long, 2 1/2 ft wide Module includes pumps,
controls, solids separator, filter system. |
| Shipping weight: |
1100 pounds approximate |
| Options: |
Additional water storage capacity. pH adjustment
system. Activated carbon water polishing system. Ozone
treatment. Pretreatment systems, oil skimmers, oily water
separators. Custom modifications available. |